Upgrade your misting system with our state-of-the-art Variable Frequency Drive (VFD) Pump. This guide will walk you through the installation process, ensuring a smooth setup and optimal performance.
Installation Steps
Step 1: Gather Necessary Tools and Parts
Before beginning the installation, ensure you have the following tools and parts:
- VFD Pump
- Nozzles (chosen based on climate)
- Fittings and connectors
- Tubing
- Solenoid valves (if not pre-installed)
- Screwdrivers, wrenches, and pliers
- Teflon tape
- Mounting hardware
Step 2: Select and Install Nozzles
- Choose Nozzle Size: Select nozzles based on your climate. For humid climates, use .008 orifice size nozzles; for dry climates, use .012 orifice size nozzles.
- Install Nozzles: Attach the selected nozzles to the tubing, ensuring they are evenly spaced for uniform misting coverage. Use Teflon tape on threads to prevent leaks.
Step 3: Mount the Pump
- Choose Location: Select an outdoor-rated location for mounting the pump, ensuring it is protected from extreme weather conditions.
- Secure the Pump: Use the provided mounting hardware to secure the pump to a stable surface. Ensure the pump is level to prevent operational issues.
Step 4: Connect Tubing and Fittings
- Attach Tubing: Connect the tubing to the pump’s outlet using appropriate fittings. Ensure all connections are tight and secure.
- Install Solenoid Valves: If your system includes internal mounted solenoid zone valves, connect them to the designated zones in your tubing layout. This allows for customized misting control.
- Run Tubing to Nozzles: Extend the tubing from the pump to the nozzle locations, making sure to route it in a way that avoids kinks and sharp bends.
Step 5: Connect Electrical Components
- Power Supply: Connect the pump to a suitable power source. Ensure the power supply matches the pump’s electrical requirements.
- Disconnect Switch: Install the disconnect switch in an accessible location to allow for easy power shutoff when needed.
Step 6: Program and Test the Pump
- Set Up Variable Speed Drive: Program the Variable Speed Drive according to your misting needs. This allows you to control the misting output precisely, optimizing energy efficiency and comfort.
- Check Low Water Protection: Ensure the low water protection programming is activated to safeguard the pump from potential damage due to low water levels.
- Test the System: Turn on the pump and observe the misting output. Check all connections for leaks and make necessary adjustments.
Features & Benefits Recap
- Heavy Duty Cat Pump: Ensures reliability and long-lasting performance.
- TEFC System: Provides optimal cooling and protection.
- Internal Mounted Solenoid Zone Valves: Allows for convenient zone control.
- Low Water Protection Programming: Prevents damage from low water levels.
- Dual Filtration System: Delivers clean, refreshing mist.
- Outdoor Rated and Weather Resistant: Built to withstand outdoor elements.
- Durable Powder Coat Finish: Adds toughness.
- Disconnect Switch: Convenient power control.
- 3-Year Warranty: Comprehensive coverage for peace of mind.
Contact Us
For more information or assistance with installation, visit us at www.aeromist.com or call 1-833-FOR-MIST.